T Manifold

The most economical structure for freeze-drying using a flask, the T-manifold allows the use of various accessories
-
T-Manifold (SUS304): Choose from 6,8,12,24 Ports (vacuum valves are installed depending on the number of ports selected)
-
Includes a special acrylic floor lid for the T-Manifold

Acrylic Base Lid + Chamber

A basic configuration that allows samples to be freeze-dried in the acrylic chamber

Acrylic Drying Chamber

An acrylic chamber that allows observation of the freeze-drying process of samples in the chamber from all angles

Stainless Drying Chamber

Allows flask freeze drying in the acrylic manifold, and the corrosion-resistant STS-304 chamber Body is applied, enhancing the chamber from corrosion caused by chemical samples
-
Acrylic Manifold Top: Choose from 6,8,12 Ports (vacuum valves are installed depending on the number of ports selected)
-
Circular Stainless Body
-
Acrylic Floor Lid: Circular (36Ø) Vacuum Guide Port

D Manifold

Allows flask freeze drying in the acrylic manifold, and the acrylic chamber Body allows observation of the freeze-drying process of samples in the chamber from all viewing angles
-
Acrylic Manifold Top: Choose from 6,8,12 Ports (vacuum valves are installed depending on the number of ports selected)
-
Circular Acrylic Body
-
Acrylic Floor Lid: Circular (36Ø) Vacuum Guide Port

3-stage shelf (Non-heating type)

-
It is possible to freeze-dry experiments by putting vials, etc. on the shelf in the chamber

4-stage Mini Tray
5-stage Mini Tray (Non-heating type)

-
Mini tray that can pre-freeze and freeze-dry in the cold trap of the freeze dryer, the material is STS-304 corrosion-resistant material
-
Choose from 4 stages, 5 stages shelf
-
Tray anti-drop pin
-
Top handle

Concentrator (Rotor)

-
A sample can be vacuum concentrated by mounting a desired concentrator rotor on the centrifugal vacuum concentrator

-
Swing rotor, 12hole, 70hole, 210 hole

Oil Mist Trap

-
A filter device that filters the oil mist generated at the outlet side when operating the vacuum pump

Adapter / Vacuum Valve / Vacuum Grease

Adapter: A device for connecting accessories such as flasks
-
Glass 45° adapter
-
Stainless 45° adapter
-
Stainless straight adapter

Vacuum valve: A valve that connects the manifold and accessories such as flasks. It forms a vacuum in the accessory or releases the vacuum.

Vacuum grease: It is applied to areas where sealing is necessary, such as valves and O-rings mounted on the freeze dryer, to effectively form a vacuum

Chemical Trap (Large/Small):

The chemical trap is a filter to protect the vacuum pump secondarily from foreign substances and corrosive materials generated from samples, cold traps, and drying chambers. It applies Active Carbon and Micron Filter for improved filtering effects and effectively protects the vacuum pump

-
Inner Filter Size :
Type A ∅Ø130 × 125L
Type B ∅Ø130 × 250L

Flask

A freeze-drying exclusive flask made of rigid first-class (Borosilicate) glass for various freeze-drying methods
-
300ml (OD∅56 × H160)
-
700ml (OD∅90 × H135)
-
900ml (OD∅90 × H190)
-
1200ml (OD∅90 × H240)
-
2000ml (OD∅120 × H225)

Caps (Type A/B/C)

Products for mounting various kinds of flasks to the freeze dryer
-
Type A (for 150ml ~ 300ml flasks)
-
Type B (for 700ml ~ 1200ml flasks)
-
Type C (for 2000ml flasks)

Pump Table

A table for mounting the freeze dryer on top and the vacuum pump on the bottom.
The horizontal fixed wheel is mounted for easy movement, and it is a table device that can adjust the level on a flat floor and fix the position

Square Heating Drying Chamber (Heating type)

Used when freeze-drying more samples than the capacity of the mini tray connected to the freeze dryer.
Designed to help quick drying by adjusting the heater (heat wind)

Tube Holder

Tube holder (STS304) is a product for standing a large number of conical tubes in the D-Type drying chamber for freeze-drying

-L : 15ml Conical Tube (124 Hole)
-M : 15ml Conical Tube (58 Hole)
-S : 15ml Conical Tube (19 Hole) / 2000ml Flask type
-L : 50ml Conical Tube (37 Hole)
-M : 50ml Conical Tube (19 Hole)
-S : 50ml Conical Tube (7 Hole) / 2000ml Flask type

Stoppering Device (Chamber / Flask)

-
After the freeze drying is finished, it automatically closes the vial cap in the stoppering, preventing exposure to cross-contamination

-
Chamber type: Use by placing vials on the shelf in the acrylic chamber (ø22mm x 140Vials)

-
Flask type: Connect with a hose to the manifold, and can use ø22mm x 24Vials

FSD Pack (Flask Sublimation Device Pack) (4L selection not possible)

It is a combination of devices that can receive sublimation heat (waste heat) through a diffuser that directs the waste heat generated in the freeze dryer towards the flask for the purpose of mounting a large capacity flask or accelerating the freeze-drying speed
-
Variable type Flask Rack body (can be purchased individually) Choose from 2Hole (4~8L body) / 4Hole (15L body)
-
WTV (Wide mouth to Vacuum valve) connector 6EA
-
Dedicated vacuum hose (4M)
-
Sublimation heat (compressor waste heat) Diffuser Kit

FPRP Filter Pack

A product that can inject or filter nitrogen (N2), clean air, or filter (up to 5µm) to prevent cross-contamination of samples after freeze drying
-
5µm vacuum release filter (1Ea)
-
N2 and purified air injection port
-
N2 injection kit (regulator, N2 injection hose 3M)

Vacuum Pump

-
A pump device that forms a vacuum connected to the freeze dryer
-
100, 200, 400, 600, 800LPM
1000, 1500, 1800LPM

Vacuum Oil

-
Available capacity: 1L, 4L